HomeMetrology DomainsTorque Facility
CHAMBER: 23.0 °C ± 1.0 °C
HUMIDITY: 50.0 % RH ± 5%
Vibration Free Mounting Bed
NABL ISO/IEC 17025 ACCREDITED 5,000 Nm PRECISION TORSION METROLOGY // CHENNAI PRIMARY LAB Traceable to NPL (India) & BIPM

Torque
CALIBRATION FACILITY

MSIR INDIA’s Torque Metrology Laboratory ensures assembly safety and joint integrity across automotive, aviation, and heavy engineering sectors. Utilizing automated torque wrench calibration benches, precision torque reaction transducers, and deadweight torque arms, we calibrate torque wrenches, screwdrivers, nutrunners, and rotary transducers in compliance with ISO 6789:2017.

TORQUE RANGE

0.1 Nm to 5,000 Nm

Clockwise & Counter-Clockwise

BEST UNCERTAINTY (CMC)

± 0.2 % of reading

Static & Dynamic

TOOL SUPPORT

Manual, Electric, Pneumatic

Assembly & Testing

STANDARD

ISO 6789:2017

Part 1 & Part 2 Conformance

LIVE METROLOGY SIGNAL SIMULATOR & TELEMETRY STUDIO

Torsion Angular Deflection & Breakaway Torque Simulator

CHANNEL 1 // TORQUE MASTER REFERENCE BUS
ACQUISITION: REAL-TIME METROLOGY (120 FPS)

MEASURED TELEMETRY

120.14

EXPANDED UNCERTAINTY (k=2)

±0.25%

TRACEABILITY

NPL India

PARAMETER TUNING

Target Torque Value:100 Nm
Thermal / Environmental Noise:
Signal Stream:
ISO/IEC 17025 Compliant Measurement

Evaluated as per GUM (JCGM 100:2008) guidelines with complete Type A and Type B expanded uncertainty analysis.

PRIMARY INSTRUMENTATION ARSENAL

Primary Reference Standards

Our torque capabilities are anchored by primary standards directly calibrated by NPL India and BIPM-recognized National Metrology Institutes.

Primary Torque StandardISO 17025

Norbar / Sturtevant Automated Torque Rig

Master Torque Wrench Calibration Rig

Motorized ball-screw loader ensuring constant angular velocity and eliminating operator-induced side forces during torque tool actuation.

Technical Highlights:

Range:0.1 Nm to 5,000 Nm
Transducer Accuracy:± 0.1 % of reading
Loading Speed:ISO 6789 compliant controlled rate
NPL India Mass & Length Traceable
ACCREDITED MEASUREMENT CAPABILITIES

Torque Scope Matrix (CMC)

Calibration & Measurement Capabilities (CMC) accredited under ISO/IEC 17025:2017. Uncertainties expressed at an expanded confidence level of approx. 95.45% (k=2).

REQUEST OFFICIAL NABL CERTIFICATE SCOPE PDF
Discipline / MeasurandCalibration RangeTest ConditionExpanded CMC (±)Master Reference StandardTest Standard / Method
Click, Dial, and Digital Torque Wrenches0.5 Nm to 3,000 NmISO 6789 Motorized Rig (CW & CCW)± 0.25 % to ± 0.8 %Norbar Master Torque Calibration SystemCalibration and measurement of uncertainty as per ISO 6789-2:2017
Torque Screwdrivers & Micro-Torque Tools0.05 Nm to 10 NmPrecision Reaction Transducer± 0.35 % of readingInterface Low-Torque Flanged TransducerIncremental static torque audit
COMPREHENSIVE EQUIPMENT DIRECTORY

Instruments Serviced & Calibrated

We calibrate all major industrial, pharmaceutical, aerospace, and research-grade instrumentation.

Adjustable Clicker Torque Wrenches

Micrometer-setting mechanical click wrenches

Electronic Digital Torque Wrenches

Digital angle and torque recording wrenches

Torque Screwdrivers & Preset Drivers

Electronics assembly ESD-safe torque tools

Pneumatic & DC Nutrunners

Production line assembly pulsed tools

METROLOGICAL INTEGRITY & RIGOR

Climate & Environment
Designed for Zero Drift

Every measurement at MSIR INDIA is conducted under strictly monitored and auditable environmental controls adhering to ISO/IEC 17025:2017:

Motor-driven loading arm preventing jerky manual impulse and side-load errors
Dual-direction calibration for both tightening and loosening directions
Pre-loading cycle run 3 times to full scale to overcome mechanical hysteresis
Strict 23 °C ambient control to maintain elasticity of internal springs

UNBROKEN CHAIN OF TRACEABILITY (ISO/IEC 17025)

TIER 1 // INTERNATIONAL DEFINITION

BIPM SI Derived Unit (Newton-Meter = N · m)

SI BASE
TIER 2 // NATIONAL METROLOGY INSTITUTE

NPL India Primary Deadweight Torque Machine

PRIMARY LAB
TIER 3 // MSIR INDIA ACCREDITED LAB

MSIR Master Norbar Rig & Flanged Transducers (NABL CC-2891)

NABL CC-2891
TIER 4 // CLIENT TEST & MEASUREMENT ASSET

Client Production Torque Wrenches and Calibration Testers

CALIBRATED
Complies fully with ILAC P10 & ISO/IEC 17025:2017 traceability policy.
INSTANT ESTIMATE & INQUIRY

Book Torque Calibration

Get an instant fee estimate for your calibration scope or book an immediate laboratory slot with our certified metrologists.

Estimated Turnaround:2 Business Days
Calibration Certificate:NABL ISO/IEC 17025
Traceability:NPL India (Dual Signatory)

INDICATIVE CALIBRATION FEE

3,000 + GST

CONFIRM & SCHEDULE INTAKE
+91 94440 28911 lab@msirindia.com

Explore All 12 Metrology Laboratories

MSIR INDIA operates 12 specialized NABL-accredited metrology domains in Chennai.

RETURN TO LABORATORY DOMAINS