HomeMetrology DomainsRF & Microwave Facility
CHAMBER: 23.0 °C ± 0.5 °C
HUMIDITY: 45.0 % RH ± 5%
EMI Attenuation > 90 dB @ 10 GHz
NABL ISO/IEC 17025 ACCREDITED 40 GHz HIGH FREQUENCY METROLOGY DIVISION // CHENNAI PRIMARY LAB Traceable to NPL (India) & BIPM

RF & Microwave
CALIBRATION FACILITY

MSIR INDIA’s RF and Microwave Metrology Laboratory provides comprehensive calibration up to 40 GHz for aerospace, radar, 5G wireless telecommunications, and defense electronics. Utilizing Keysight PNA-X microwave network analyzers, Rohde & Schwarz signal analyzers, and primary thermistor power sensors, we calibrate power, attenuation, S-parameters, phase noise, and spectrum fidelity.

FREQUENCY RANGE

10 kHz to 40 GHz

Coaxial & Waveguide

POWER DYNAMIC RANGE

-130 dBm to +30 dBm

Sub-Nanowatt to Watts

ATTENUATION CMC

± 0.05 dB

To 40 GHz

PRIMARY ANALYZER

Keysight PNA-X

67 GHz 4-Port Microwave

LIVE METROLOGY SIGNAL SIMULATOR & TELEMETRY STUDIO

High-Frequency Spectrum Sweep & FFT Waveform Analyzer

CHANNEL 1 // RF & MICROWAVE MASTER REFERENCE BUS
ACQUISITION: REAL-TIME METROLOGY (120 FPS)

MEASURED TELEMETRY

-10.02

EXPANDED UNCERTAINTY (k=2)

±0.04 dB

TRACEABILITY

NPL India

PARAMETER TUNING

RF Carrier Frequency:5 GHz
Thermal / Environmental Noise:
Signal Stream:
ISO/IEC 17025 Compliant Measurement

Evaluated as per GUM (JCGM 100:2008) guidelines with complete Type A and Type B expanded uncertainty analysis.

PRIMARY INSTRUMENTATION ARSENAL

Primary Reference Standards

Our rf & microwave capabilities are anchored by primary standards directly calibrated by NPL India and BIPM-recognized National Metrology Institutes.

Primary S-Parameter StandardISO 17025

Keysight N5247B PNA-X

Microwave Network Analyzer 67 GHz

Industry flagship 4-port vector network analyzer with electronic calibration (ECal) modules and precision air-line mechanical verification kits.

Technical Highlights:

Freq Range:10 MHz to 67 GHz
Dynamic Range:> 130 dB
Trace Noise:< 0.001 dB rms
Keysight Primary Microwave Standards
RF Frequency & Amplitude MasterISO 17025

Rohde & Schwarz FSV3044

Signal and Spectrum Analyzer 44 GHz

Ultra-low phase noise signal analyzer for harmonic distortion, third-order intercept (TOI), and frequency accuracy.

Technical Highlights:

Frequency:10 Hz to 44 GHz
Analysis Bandwidth:200 MHz
Phase Noise:< -130 dBc/Hz @ 1 GHz
NPL India / PTB Traceable
ACCREDITED MEASUREMENT CAPABILITIES

RF & Microwave Scope Matrix (CMC)

Calibration & Measurement Capabilities (CMC) accredited under ISO/IEC 17025:2017. Uncertainties expressed at an expanded confidence level of approx. 95.45% (k=2).

REQUEST OFFICIAL NABL CERTIFICATE SCOPE PDF
Discipline / MeasurandCalibration RangeTest ConditionExpanded CMC (±)Master Reference StandardTest Standard / Method
RF Power Sensors & Power Meters-70 dBm to +30 dBm (10 MHz to 40 GHz)Precision Coaxial Coaxial Mount± 0.025 dB to ± 0.09 dBPrimary Thermistor Power Standard + DC ReferenceDirect comparison transfer standard method
Spectrum Analyzers (Frequency & Amplitude)9 kHz to 40 GHz (Level: -100 to +10 dBm)Harmonic & Spurious Verification± 0.15 dB Amplitude, ± 2×10⁻¹¹ FreqRubidium Atomic Clock + Synthesized GeneratorCalibrated stepped level & frequency marker verification
RF Attenuators & Termination Loads (VSWR / S-Parameters)0 to 70 dB attenuation (up to 40 GHz)50 Ω Characteristic Impedance± 0.05 dB (Attenuation), ± 0.015 (Reflection Γ)Keysight PNA-X VNA + Precision Air LinesVector network S-parameter substitution metrology
COMPREHENSIVE EQUIPMENT DIRECTORY

Instruments Serviced & Calibrated

We calibrate all major industrial, pharmaceutical, aerospace, and research-grade instrumentation.

Spectrum & Signal Analyzers

Keysight, R&S, Anritsu up to 40 GHz

Vector Network Analyzers (VNA)

S11, S21, S12, S22 magnitude & phase verification

RF Signal Generators & Synthesizers

CW, AM, FM, Phase, Pulse and digital modulation

RF Power Meters & Sensors

Average, peak, and thermocouple power sensors

Step & Fixed Attenuators

High-precision coaxial attenuators and pads

METROLOGICAL INTEGRITY & RIGOR

Climate & Environment
Designed for Zero Drift

Every measurement at MSIR INDIA is conducted under strictly monitored and auditable environmental controls adhering to ISO/IEC 17025:2017:

Continuous RF-tight semi-anechoic Faradaic shielded bay with honeycomb air vents
All RF cables utilize phase-stable silver-plated Gore-Tex dielectric assemblies
Calibrated torque wrenches used on all 3.5mm, 2.92mm (K), and 2.4mm connectors
Rubidium atomic clock distribution feed to all instruments on the RF bench

UNBROKEN CHAIN OF TRACEABILITY (ISO/IEC 17025)

TIER 1 // INTERNATIONAL DEFINITION

BIPM SI Derived Units (Hertz, Watt, Decibel)

SI BASE
TIER 2 // NATIONAL METROLOGY INSTITUTE

NPL India Radio Frequency Metrology Standards

PRIMARY LAB
TIER 3 // MSIR INDIA ACCREDITED LAB

MSIR Master Keysight PNA-X & R&S FSV3044 (NABL CC-2891)

NABL CC-2891
TIER 4 // CLIENT TEST & MEASUREMENT ASSET

Client Microwave Receivers, Radar Front-Ends, and Spectrum Analyzers

CALIBRATED
Complies fully with ILAC P10 & ISO/IEC 17025:2017 traceability policy.
INSTANT ESTIMATE & INQUIRY

Book RF & Microwave Calibration

Get an instant fee estimate for your calibration scope or book an immediate laboratory slot with our certified metrologists.

Estimated Turnaround:2 Business Days
Calibration Certificate:NABL ISO/IEC 17025
Traceability:NPL India (Dual Signatory)

INDICATIVE CALIBRATION FEE

3,000 + GST

CONFIRM & SCHEDULE INTAKE
+91 94440 28911 lab@msirindia.com

Explore All 12 Metrology Laboratories

MSIR INDIA operates 12 specialized NABL-accredited metrology domains in Chennai.

RETURN TO LABORATORY DOMAINS