HomeMetrology DomainsDimensions Facility
CHAMBER: 20.0 °C ± 0.2 °C (ISO 1 Standard)
HUMIDITY: 45.0 % RH ± 5%
Acoustic & Thermal Drift Isolation
NABL ISO/IEC 17025 ACCREDITED SUB-MICRON LENGTH & GEOMETRY METROLOGY // CHENNAI PRIMARY LAB Traceable to NPL (India) & BIPM

Dimensions
CALIBRATION FACILITY

The MSIR INDIA Dimensional Metrology Laboratory strictly adheres to the ISO 1 international standard reference temperature of 20.0 °C. Equipped with Renishaw XL-80 laser interferometers, Grade 0 ceramic and tungsten carbide gauge block masters, Talyrond roundness testers, and automated optical micrometers, we deliver dimensional verification for aerospace tooling and precision machining.

LASER RESOLUTION

0.0001 mm (0.1 µm)

Renishaw XL-80

MEASURING RANGE

0 to 1,000 mm

Linear Metrology

FLATNESS STANDARD

λ / 20 (0.03 µm)

Monochromatic Flat

CHAMBER TEMP

Strict 20.0 °C

ISO 1 Standard Baseline

LIVE METROLOGY SIGNAL SIMULATOR & TELEMETRY STUDIO

Laser Optical Interference Fringe & Micron Grating Simulator

CHANNEL 1 // DIMENSIONS MASTER REFERENCE BUS
ACQUISITION: REAL-TIME METROLOGY (120 FPS)

MEASURED TELEMETRY

25.00012

EXPANDED UNCERTAINTY (k=2)

±0.05 µm

TRACEABILITY

NPL India

PARAMETER TUNING

Nominal Dimension Length:25 mm
Thermal / Environmental Noise:
Signal Stream:
ISO/IEC 17025 Compliant Measurement

Evaluated as per GUM (JCGM 100:2008) guidelines with complete Type A and Type B expanded uncertainty analysis.

PRIMARY INSTRUMENTATION ARSENAL

Primary Reference Standards

Our dimensions capabilities are anchored by primary standards directly calibrated by NPL India and BIPM-recognized National Metrology Institutes.

Primary Dimensional ReferenceISO 17025

Renishaw XL-80 Laser Interferometer

HeNe Laser Length Standard

Frequency-stabilized helium-neon laser system with automated environmental compensation for air temperature, pressure, and relative humidity.

Technical Highlights:

Linear Accuracy:± 0.5 ppm over full range
Resolution:1 nm (0.001 µm)
Wavelength:632.8 nm (He-Ne)
NPL India Laser Metrology Direct Traceability
Length Comparison StandardsISO 17025

Mitutoyo Grade 0 Gauge Block Sets

Ceramic & Steel Master Gauge Blocks

Ultra-flat wringing gauge blocks used for comparative mechanical calibration of micrometers, calipers, and height gauges.

Technical Highlights:

Grade:ISO 3650 Grade 0
Thermal Expansion:9.3 × 10⁻⁶ / °C (Ceramic)
Sizes:0.5 mm to 1,000 mm
Interferometric Calibration Certificate
ACCREDITED MEASUREMENT CAPABILITIES

Dimensions Scope Matrix (CMC)

Calibration & Measurement Capabilities (CMC) accredited under ISO/IEC 17025:2017. Uncertainties expressed at an expanded confidence level of approx. 95.45% (k=2).

REQUEST OFFICIAL NABL CERTIFICATE SCOPE PDF
Discipline / MeasurandCalibration RangeTest ConditionExpanded CMC (±)Master Reference StandardTest Standard / Method
Gauge Blocks & Length Standards0.5 mm to 1,000 mmMonochromatic Interferometer & Comparator± (0.05 + 0.5L) µmRenishaw Laser Interferometer + Grade 0 BlocksInterferometry & mechanical comparison (ISO 3650)
External/Internal Micrometers, Calipers, Height Gauges0 to 1,000 mmStrict 20.0 °C Thermal Equilibrium± 1.2 µm to ± 8.0 µmMaster Gauge Blocks + Optical FlatsStep check and flatness evaluation (IS 2967 / ISO 13385)
Surface Plates (Granite & Cast Iron)Up to 3,000 mm × 2,000 mmElectronic Differential Levels / Autocollimator± 1.5 µm overall planarityWyler Precision Electronic Inclination LevelsUnion Jack grid method as per IS 7327 / BS 817
COMPREHENSIVE EQUIPMENT DIRECTORY

Instruments Serviced & Calibrated

We calibrate all major industrial, pharmaceutical, aerospace, and research-grade instrumentation.

Vernier & Digital Calipers

Depth, internal, external calipers up to 2,000 mm

Micrometers (Outside, Inside, Depth)

Mechanical and digital micrometers

Dial Indicators & Bore Gauges

Plunger and lever dial test indicators

Height Gauges & Profile Projectors

Electronic height masters and optical comparators

Granite Surface Plates & Straightedges

On-site computerized planarity & flatness mapping

METROLOGICAL INTEGRITY & RIGOR

Climate & Environment
Designed for Zero Drift

Every measurement at MSIR INDIA is conducted under strictly monitored and auditable environmental controls adhering to ISO/IEC 17025:2017:

Continuous thermal soaking of client gauges for 24 hours prior to measurement
Air temperature maintained strictly at 20.0 °C ± 0.2 °C with zero direct air draft
Granite master calibration stations resting on isolated concrete pillars
Interferometric air refraction index compensation using Edlén formula

UNBROKEN CHAIN OF TRACEABILITY (ISO/IEC 17025)

TIER 1 // INTERNATIONAL DEFINITION

BIPM SI Meter Definition (Speed of Light c in Vacuum)

SI BASE
TIER 2 // NATIONAL METROLOGY INSTITUTE

NPL India Iodine-Stabilized HeNe Laser Primary Standard

PRIMARY LAB
TIER 3 // MSIR INDIA ACCREDITED LAB

MSIR Master Renishaw XL-80 Laser Interferometer (NABL CC-2891)

NABL CC-2891
TIER 4 // CLIENT TEST & MEASUREMENT ASSET

Client Precision Gauge Blocks, CMMs, and Micrometers

CALIBRATED
Complies fully with ILAC P10 & ISO/IEC 17025:2017 traceability policy.
INSTANT ESTIMATE & INQUIRY

Book Dimensions Calibration

Get an instant fee estimate for your calibration scope or book an immediate laboratory slot with our certified metrologists.

Estimated Turnaround:2 Business Days
Calibration Certificate:NABL ISO/IEC 17025
Traceability:NPL India (Dual Signatory)

INDICATIVE CALIBRATION FEE

3,000 + GST

CONFIRM & SCHEDULE INTAKE
+91 94440 28911 lab@msirindia.com

Explore All 12 Metrology Laboratories

MSIR INDIA operates 12 specialized NABL-accredited metrology domains in Chennai.

RETURN TO LABORATORY DOMAINS