HomeMetrology DomainsPressure & Vacuum Facility
CHAMBER: 20.0 °C ± 0.5 °C
HUMIDITY: 45.0 % RH ± 5%
Vibration Isolated Concrete Pedestal
NABL ISO/IEC 17025 ACCREDITED HIGH-PRESSURE METROLOGY DIVISION // CHENNAI PRIMARY LAB Traceable to NPL (India) & BIPM

Pressure & Vacuum
CALIBRATION FACILITY

The MSIR INDIA Pressure Metrology Laboratory specializes in pneumatic and hydraulic pressure calibration across 7 orders of magnitude. Using automated deadweight testers with tungsten carbide piston-cylinder units, localized gravity compensation (g = 9.7828 m/s²), and high-stability quartz transducers, we serve aerospace, oil & gas, process industries, and defense standards.

PRESSURE RANGE

-1 bar to 2,500 bar

Vacuum to Ultra-High

BEST UNCERTAINTY (CMC)

± 0.005 % of reading

Hydraulic Deadweight

FLUID MEDIA

Gas, N2, Oil, Water

Non-Contaminating

AUTOMATION

Druck PACE6000

Dual Channel High-Speed

LIVE METROLOGY SIGNAL SIMULATOR & TELEMETRY STUDIO

Deadweight Piston Flotation & Equilibrium Simulator

CHANNEL 1 // PRESSURE & VACUUM MASTER REFERENCE BUS
ACQUISITION: REAL-TIME METROLOGY (120 FPS)

MEASURED TELEMETRY

250.004

EXPANDED UNCERTAINTY (k=2)

±0.005%

TRACEABILITY

NPL India

PARAMETER TUNING

Target Pressure Setpoint:100 bar
Thermal / Environmental Noise:
Signal Stream:
ISO/IEC 17025 Compliant Measurement

Evaluated as per GUM (JCGM 100:2008) guidelines with complete Type A and Type B expanded uncertainty analysis.

PRIMARY INSTRUMENTATION ARSENAL

Primary Reference Standards

Our pressure & vacuum capabilities are anchored by primary standards directly calibrated by NPL India and BIPM-recognized National Metrology Institutes.

Primary Pressure StandardISO 17025

WIKA CPB5000

Hydraulic Deadweight Tester (Piston Gauge)

Tungsten carbide piston-cylinder assembly with high-precision austenitic stainless steel mass sets for primary pressure generation up to 2,500 bar.

Technical Highlights:

Pressure Range:Up to 2,500 bar (36,000 psi)
Accuracy:± 0.005 % of reading
Piston Material:Tungsten Carbide
NPL India Mass & Area Traceable
High-Precision Automated StandardISO 17025

Druck PACE 6000

Modular Pneumatic Pressure Controller

Dual-channel piezo-resistive and resonant quartz pressure sensors for ultra-fast, overshoot-free calibration up to 210 bar.

Technical Highlights:

Control Stability:0.001 % F.S.
Measurement Precision:0.005 % Rdg + 0.005 % FS
Media:Clean Dry Air / Nitrogen
ISO/IEC 17025 Accredited
ACCREDITED MEASUREMENT CAPABILITIES

Pressure & Vacuum Scope Matrix (CMC)

Calibration & Measurement Capabilities (CMC) accredited under ISO/IEC 17025:2017. Uncertainties expressed at an expanded confidence level of approx. 95.45% (k=2).

REQUEST OFFICIAL NABL CERTIFICATE SCOPE PDF
Discipline / MeasurandCalibration RangeTest ConditionExpanded CMC (±)Master Reference StandardTest Standard / Method
Pneumatic Low Pressure & Vacuum Gauges-0.95 bar to 20 barClean Nitrogen Gas± 0.01 % of readingDruck PACE 6000 ControllerDirect comparison (DKD-R 6-1)
Hydraulic Pressure Transmitters & Master Gauges10 bar to 2,500 barSynthetic Sebacate / Mineral Oil± 0.005 % of readingWIKA CPB5000 Hydraulic Deadweight TesterCross-float and direct deadweight generation (BS EN 837)
Differential Pressure (DP) Transmitters0 to 1,000 mbar at static pressure to 100 barDual Port Automated± 0.02 % of spanResonant Quartz Transfer StandardHigh line pressure differential comparison
COMPREHENSIVE EQUIPMENT DIRECTORY

Instruments Serviced & Calibrated

We calibrate all major industrial, pharmaceutical, aerospace, and research-grade instrumentation.

Analog & Digital Master Gauges

0.05% to 0.25% class test gauges

Pressure Transmitters (HART/4-20mA)

Industrial process transducers & transmitters

Differential Pressure Transmitters

Flow orifice & filter monitoring DP cells

Safety Relief Valves (SRV / PSV)

Pop test, reseat pressure & bubble leak checks

Barometers & Altimeters

Atmospheric pressure aviation reference units

Vacuum Gauges (Pirani / Capacitance)

Rough to high vacuum instrumentation

METROLOGICAL INTEGRITY & RIGOR

Climate & Environment
Designed for Zero Drift

Every measurement at MSIR INDIA is conducted under strictly monitored and auditable environmental controls adhering to ISO/IEC 17025:2017:

Independent seismic isolated granite foundation dampening building vibrations
Local acceleration of gravity (g) surveyed and applied to all deadweight calculations
Closed-loop oil cleaning system preventing cross-contamination of client media
Continuous thermal gradient logging to correct for piston-cylinder thermal expansion

UNBROKEN CHAIN OF TRACEABILITY (ISO/IEC 17025)

TIER 1 // INTERNATIONAL DEFINITION

BIPM SI Derived Unit (Pascal = N/m²)

SI BASE
TIER 2 // NATIONAL METROLOGY INSTITUTE

NPL India Primary Ultrasonic Mercury Manometer & DWT

PRIMARY LAB
TIER 3 // MSIR INDIA ACCREDITED LAB

MSIR Master CPB5000 Tungsten Carbide Piston Gauge (NABL CC-2891)

NABL CC-2891
TIER 4 // CLIENT TEST & MEASUREMENT ASSET

Client Pressure Transmitters, Master Gauges, and Safety Valves

CALIBRATED
Complies fully with ILAC P10 & ISO/IEC 17025:2017 traceability policy.
INSTANT ESTIMATE & INQUIRY

Book Pressure & Vacuum Calibration

Get an instant fee estimate for your calibration scope or book an immediate laboratory slot with our certified metrologists.

Estimated Turnaround:2 Business Days
Calibration Certificate:NABL ISO/IEC 17025
Traceability:NPL India (Dual Signatory)

INDICATIVE CALIBRATION FEE

3,000 + GST

CONFIRM & SCHEDULE INTAKE
+91 94440 28911 lab@msirindia.com

Explore All 12 Metrology Laboratories

MSIR INDIA operates 12 specialized NABL-accredited metrology domains in Chennai.